Effective Air Disinfection System UVR
UVC Recirculators are effective against common airborne diseases by disinfecting the air and efficiently destroying disease-causing agents (viruses, microorganisms) by UVC radiation.
UVR Recirculators are ideal for air disinfection in hospitals (outpatient departments, operating rooms, emergency rooms, delivery rooms etc.), kindergartens, research laboratories, veterinary clinics, schools, offices, etc.
The devices provide complete protection from direct ultraviolet radiation.
The exact article number can be found in the technical data.
Request a quoteEffective Air Disinfection System UVR
The principle of these air purifiers is based on constant, forced air circulation, which is channelled directly past a UV lamp. Due to the mirrored inner surface in the circulation chamber, UV rays are repeatedly reflected, which increases the UV radiation density and therefore intensifies the disinfection effect. This ensures maximum disinfection efficiency.
The devices consist of a germicidal UV lamp, a fan equipped with dust filters and a control unit built into the housing.
Advantages of UVR-Mi
- UVR-Mi is the more powerful model of UV air flow
- cleaner with two UV-lamps
- Full user protection from direct UV radiation;
- Two operation modes - short time (under timer control) and continuous operation;
- Indication of UV lamps working hours.
Recirculators Fixation
- Convenient fixation on walls (standard)
- Mounting on a movable tripod (optional)
Model | UVR-M | UVR-Mi |
---|---|---|
Order number | 110.5200 | 110.5201 |
Figure | ||
UV radiation source | 1 x 25 Watt Bactericidal UV-C TUV 25W 1SL/25 | 2 x 25 Watt Bactericidal UV-C TUV 25W 1SL/25 |
UV emission intensity (averaged) | 18 mW / cm2 / sec | 36 mW / cm2 / sec |
Radiation type | UV (λ = 253.7 nm), ozone-free | UV (λ = 253.7 nm), ozone-free |
Air-flow productivity Volume per hour | 21 m³/hour | 29 m³/hour |
Full user protection from direct UV light | yes | yes |
Display | - | LCD |
UV lamp operation indicator | yes | yes |
UV lamp lifetime counter | - | yes |
Timer | - | 1 min - 24 hours / non-stop |
Automatic switch ON/OFF | - | yes |
Lamp fault detection | - | yes |
Dimensions (W x D x H) | 135 x 110 x 660 mm | 135 x 110 x 660 mm |
Weight | 3.4 kg | 3.4 kg |
Nominal operating voltage | 230 V, 50 Hz | 230 V, 50 Hz |
Power consumption | 125 Watt (540 mA) | 110 W (0.5 A) |
UVR-S Stand (option) | ||
Dimensions Stand | 600 x 600 x ~1100 mm | 600 x 600 x ~1100 mm |
Part number stand (UVR-S) | 110.5205 | 110.5205 |
How efficient is UV-Cleaner Recirculator?
UV Cleaner-Recirculator is efficient against most microorganisms. Experimental data of Biosan`s UV Cleaner-Recirculator efficiency of DNA amplicon decontamination can be found here.
Is the stand included in delivery?
No, but it can be ordered separately (Item No. 110.5205)
What are the main application areas for UVR-M?
Recirculators are effective against common airborne diseases by disinfecting the air and efficiently destroying disease-causing agents (viruses, microorganisms) by UV radiation. UV Air Recirculators are ideal for air disinfection in hospitals (outpatient departments, operating rooms, emergency rooms, delivery rooms etc.), kindergartens, research laboratories, veterinary clinics, schools, offices, etc. .
How long is a service life of a UV-lamp?
Average lifetime of UV lamps supplied is 9000 h. That is equivalent to 1 year of non-stop use everyday for 24h.
Which room capacity can be cleaned by one UV-recirculator?
The number of UV recirculators required for 90% efficiency of room air decontamination (in 1 hour):