PCR Thermal Cycler Turbo 2

An affordable and compact PCR cycler with an A4 footprint. With integrated 7-inch touch screen and easy-to-understand user interface.

Efficiency and accuracy have been enhanced by a faster slew rate and significant gradient optimization.

Applications

  • PCR
  • CRISPR assays
  • NGS sample preparation
Request a quote

PCR Thermocycler Turbo2

Outstanding Performance

  • Proven Peltier technology for trouble-free heating and cooling.
  • Fast heating rate up to 5.5 °C/sec
  • Excellent temperature accuracy and uniformity (+/- 0,3 °C)
  • 12-section gradient temperature range from 1 to 24.9°C for  PCR optimization
  • Quick boot-up in only 45 seconds

Intuitive Operation Experience 

The sensitive 7" capacitive touchscreen enables easy operation even with laboratory gloves on.

Convenient Tools

The built-in tools allow easy Tm calculation, copy number conversion and master mix preparation.

User-friendly interface

The simple conversational graphic user interface, which has intuitive spinning wheels, makes adjustment of experiment temperature, time and cycle easy.

Heated Lid
Automatic pressure-controlled and heatable lid to prevent condensation.

Multi Probe Temperature Detection System
For calibration and QC process.

USB-Port
For protocol and run log output via USB flash drive.

Wi-Fi-Modul (optional)
Allows monitoring PCR run status anytime via mobile devices using the free TurboApp.

Order No.112.6010
Sample Block 
Gradient Block96-Well, compatible with regular profile or low profile 0.2 ml PCR tube, strip
none-skirted, semi-skirted and full-skirted 96-well plate
Sample Volume10 – 100 µl
Block Temperature 
Block Temperature Range4.0 – 100 °C
Max. Heating Rate5.5 °C/sec
Max. Cooling Rate3.3 °C/sec
Temperature Accuracy± 0.3 °C
Temperature Uniformity Across Block± 0.3 °C
Adjustable Ramp Rate0.1 – 5.5 °C/sec
Gradient Temperature 
Gradient DirectionHorizontal across the block
Gradient Temperature Range30 – 100 °C
Gradient Temperature DifferenceMax.  span 30 °C
Heater Lid 
Temperature Setting Range35 – 120 °C or off
Temperature Accuracy± 1.0 °C
Software 
Portability of ProtocolsSave and transfer to computer or TurboCycler 2 via USB flash drive
Stored Program No.> 4000 sets
Registered User Folder No.100 sets
User Folder Password ProtectionYes
Run Status ReportYes, HTML output and transfer via USB flash drive
Real-time Temp. Profile ExportYes, CSV output and transfer via USB flash drive
ToolsTm calculator, Copy number convertor, Master mix preparation wizard
General 
Display7" color LCD with capacitive touch panel
Data port1 USB Type-A front port for USB flash drive
Heated Lid35 – 102 °C or off
Auto Restart after Power OutageYes
Remote Motoring via Wi-FiOption
Footprint Dimensions (H x W x D)225 x 245 x 415 mm
Volume
(Measuring distance approx. 40 cm)
Heating noise: ~46 db
Cooliong noise: ~56 db
Weight9.5 kg
Power SupplyAC 100-240 V, 50/60 Hz, 750 W
CertificationCE, RoHS

 

Compression Mat and Low-profile PCR vessel

The low-profile PCR vessel is designed to reduce the overhead space above the reaction solution inside the vessel.

During the thermal cycling, the water in the solution evaporate and fill up the overhead space, causing the concentration increase of the reacting solution.

The smaller overhead space, the fewer water evaporated, thus reduce the concentration change of the solution when heated. This will be helpful especially when you are doing low volume reaction.

In general, the low-profile PCR vessels are 5 mm shorter in height than the regular PCR vessels.

In order to maintain the pressure from the cycler lid to the vessels, please apply the compressor mat for the experiment and set the lid to heat to 120°C.

What is the function of the heated lid?

The advantage of the heated lid is that strong condensation in the PCR tubes during the reaction is avoided.
The condensation in the tubes depends, among other things, on the sealing of the PCR tubes.
The lid helps to exert the correct pressure on the sealed tubes, thus ensuring a perfect seal and preventing condensation inside the tubes.

There are three different temperature settings for the lid:

  1. 120°C (for use with low-profile-vessel and compression mat), with extra 3 min pre-heat
  2. 105°C
  3. Heater off

Thermo-cycling is not possible with the lid heating itself.

If the block drops below 30°C, the lid heating stops. The temperature of the lid drops gradually.

Condensation versus evaporation

The condensation inside the tubes is mainly caused by the fact that they have been kept at a lower temperature (e.g. 4°C) for a longer period of time after running. This occurs with all cyclers. This phenomenon is similar to placing a bottle of water in the refrigerator - you will see the condensate in the bottle.

When I start a run, the block hold for several minutes then start to heat. Why?

The lid of the cycler need to be heated to proper temperature first then the block start to heat. According to the setting of the lid temperature, the room temperature and the usage of the compression mat, it can take 2-8 minutes for the lid the finish the heating.

When the power comes back after a power failure, does the cycler start running again?

For the power-failure-during-a-run situation, when the power come back to the unit, the unit will start from what is was running (without touch the power switch) and finish the protocol.
Also, if the power failure for long time, the unit will start (after the power back on) as well but it will take few seconds or minute for lid module heat up.
After the lid module reach to the setting temperature, the protocol will be continued. This design will protect the PCR experiment.
This funcion named "auto-restart after power outage".

Can TurboCycler run overnight?

Yes! But we would not recommend you do that really often.
Running your cycler overnight at 4°C potentially reduce the life cycle of the instrument. In most application, 16°C instead of 4°C for overnight storage can well-protect your DNA sample.

Whether the ramping rate of TurboCycler is adjustable?

Yes! There are two options of the ramping rate for the TurboCycler, High and Low.
High for the full ramping power that will speed up your experiment and Low for the 50% of the ramping power that can mimic the running condition on the other older generation cyclers.

Is the block of the TurboCycler interchangeable?

There is only one block configuration so far, so it is not interchangeable.
However, if there is any service need to be done with the block, it can be easily disassembled and sent back to us for service.