Real-Time Cycler BioQuant-96
BioQuant - 96 PCR Cycler
BioQuant is an innovative Real-Time cycler for molecular diagnostics and offers innovative thermoelectric cooling technology and optimised light sources.
Detection from the top allows using different consumables:
- 0,2 ml tubes
- 8 strip-tubes
- 96 well PCR plates semi-skirted and non-skirted
The unique constant current power and 6-zone independent temperature control method ensure more rapid, correct and stable fluorescence quantitative analysis, while maintaining its excellent performance in lowest possible energy consumption.
Request a quoteRT-Cycler BioQuant-96
Device is available in 5-channel and 6-channel configuration. Meanwhile, it has been added with functions including independent temperature control, low temperature storage of sample at 4°C and FAST mode for more faster cycling (confirm reagent compatibility with fast mode).
BioQuant-96 is comprehensively realizing automatic gain setting and improving user experience.
It will fully meet the demand of scientific research laboratories and registered as I (A) class Medical device in EU it also will fully meet the requirements of any diagnostic laboratory.
Sample capacity | 0.2ml single tube (transparent cap) 96 × 0.2 (0.1) ml Plate (transparent cap), 8-strip tubes (transparent cap) |
Dynamic range | 1 ~ 10^10 copies |
Excitation wavelength | 300 – 800 nm |
Emission wavelength | 500 – 800 nm |
Channels | 5 |
Temperature setting range | 4 ~ 105°C (increment: 0.1°C) |
Heating/cooling rate | Max 6.0 °C/s / 5.5 °C/s |
Temperature accuracy | ≤ ±0.1°C |
Temperature fluctuation | ≤ ±0.3°C |
Temperature uniformity | ≤ ±0.3°C |
Temperature control mode | Block / 6-zone gradient |
Sample volume | 5 ~ 100 μl |
Gradient temperature range | 1 ~ 36°C |
Hot-lid temperature range | 30 ~ 110 °C (adjustable default: 105°C, automatic Hot-lid) |
Repeatability | 5% |
Scan mode | Full plate simultaneously |
Program | Max. 20 segments for each program, max. 99 cycles |
Continuous operation | + |
Scan period | 5.5 s |
Software | BioQuant-96 Software |
Operating system | Windows 7/8/10 |
Software required | Microsoft Excel |
Minimum PC requirements | Built-in touchscreen-PC / Memory: 512 MB, Hard disc: 10 GB, CPU: Pentium® 4, Virtual memory: ≥ 1000 MB |
Nominal operating voltage | 100 – 240V; 50/60Hz |
Power consumption | 600 W |
Dimensions (W x D x H) | 490 × 290 × 391 mm |
Number of sockets | USB adapter, Bluetooth adapter |
Certification | CE, IVD |
Interface | WIN 10 on built-in touchscreen PC |